Product Profile of On-Line Double Conversion type Uninterrupted Power Supply System
NIFA Electronics Pvt. Ltd supplies On-Line Double Conversion type Uninterrupted Power Supply System. NIFA Electronics Pvt. Ltd offers a wide range of products based on power conditioning and power management like inverters, stabilizers, voltage regulators, transformers, capacitors and control relays. The On-Line Double Conversion type Uninterrupted Power Supply System available in the brand name "Power Master" provides clean power and total protection to costly electrical equipments. The On-Line Double Conversion type Uninterrupted Power Supply System finds application in Medical Diagnostic Systems, Banking Terminals, Communication Systems and Chemical and R & D Labs.
Key Features of On-Line Double Conversion type Uninterrupted Power Supply System
- VHD Logic
- High Frequency PWM Design using IGBT / MOSFET
- Instantaneous sine wave reference technique for superior overall performance.
- Compact and well engineered architecture.
- Wide input voltage tolerance range.
- Suitable for all types and capacities of batteries.
- Neat and clean Flat Cable Wiring.
- Pure Sine Wave Output.
- Smooth and silent operation.
- Complete annunciation on the front panel.
- Excellent dynamic response for step load change.
- Fast correction rate for line and load regulation.
- High inrush / peak current handling capacity.
- Software interface through RS 232 port for monitoring UPS performance from server.
- Easy to install, use and maintain.
- Rated Output Capacity: 0.5 KVA to 40.0 KVA Single Phase
- Input Voltage: 160-270 V AC Two Wire, 30-470 V AC Four Wire.
- Input Frequency: 47-53 Hzs
- Battery Type: S.M.F. / Tubular or any other type for 15 min to 5.0 hrs.
- Output Voltage: 220 / 230 V AC
- Regulation: ± 1% under all Line and Load Conditions.
- Output Frequency: 50.0 Hzs.
- Regulation: ± 0.25%
- Inverter Efficiency: 88 - 90% or better
- Distortion: THD less than 2%, Any Single Harmonic less than 1%
- Transient Response: ± 3% under step Load Change of 80%
- Transient Recovery: Within 5 - 10ms in regulation band
- Load Power Factor: Unity to .65 Lag within KW Rating
- Overload Capacity: 120% for 10 mins. 150% for 10 sec.
- Crest Factor: Better than 2.5
- Switching Frequency: 6 KHz / 12 KHz / 24 KHz
- Ambient Temperature: 0 - 50 Degrees Celsius
- Relative Humidity: 95% RH Max. [Non Condensing]
- Audible Noise: 45 - 55 dB at 1.5 meters.
- Data Processing Equipment
- Process Automation Systems
- Medical Diagnostic Systems
- Office and Factory Automation
- Satellite Earth Stations
- Defence and Nuclear Facilities
- Machine Tools and Robotics
- ICUs, OTs and Laboratories
- Power Generation Stations
- Prepress and Printing Equipment
Product Specification of On-Line Double Conversion type Uninterrupted Power Supply System
- Ambient Temperature:0 - 50°C
- Audible Noise:45 - 55 dB at 1.5 meters
- Battery Type:S.M.F. / Tubular or any other type for 15 min. to 5.0 hrs. as per req
- Control Method:Double edge PWM with instantaneous control
- Cooling:Forced Air Type
- Crest Factor:Better than 2.5
- Distortion:THD less than 2%, Any Single Harmonic less than 1%
- Input Frequency Range:47-53 Hzs
- Input Voltage:160-270 V AC Two Wire
330-470 V AC Four Wire
- Inverter Efficiency:88 - 90% or better
- Load Power Factor (PF):Unity to 65 Lag within KW Rating
- Output Voltage:220 / 230 V AC
- Overload Capacity:120% for 10 mins. 150% for 10 sec
- Rated Output Capacity:0.5 KVA to 40.0 KVA Single Phase
- Regulation:± 0.25%
- Relative Humidity:95% RH Max (Non Condensing)
- Transient Recovery:Within 5 - 10ms in regulation band
- Transient Response:± 3% under step Load Change of 80%
- Waveform:Sinusoidal