Product Profile of Micro Switches With Regular Or Sealed Operating Heads
VG Electric offers Micro Switches with Regular or Sealed Operating Heads. VG Electric supplies micro switches; limit switches, Push Button switches, pilot /indicator lights, cam operated rotary switches, sensors, etc. The features of Micro Switches with Regular or Sealed Operating Heads are completely sealed constructure with wide choice of heads and actuators.
Key Features of Micro Switches With Regular Or Sealed Operating Heads
- Regular or sealed operating heads
- Momentary contacts
- Completely sealed constructure
- Wide choice of heads and actuators
- Temperature range +5§F to 175§F [ -15§C to +80§C]
- Plastic [Standard] or phenolic housing
- Regular or light operating force
- 15A: 125 or 250V AC
- 1/8 HP: 125V AC
- 1/4 HP: 250V AC
- 1/2A: 125V DC
- 1/4A: 250V DC
- Operating speed: 0.01mm to 1m/sec
- Operating frequency: Mechanically: 240 operations/min.; Electrically: 20 operations/min.
- Contact resistance: 15m ? min. [at 500 VDC]
- Insulation resistance: 100M ? min. [at 500 VDC]
- Dielectric strength: 1,000 VAC, 50/60 Hz for 1 minute between non-continuous terminals; 2,000 VAC, 50/60 Hz for 1 minute between current-carry part and ground
- Vibration: Malfunction durability: 10 to 55Hz 1.5mm double amplitude
- Shock: Mechanical durability: Approx 1,000m/sec [approx 100G`s]
- Malfunction durability: Approx. 300m/sec [approx 30G`s]
- Ambient operating temperature: General purpose type: -25§ to +80§ C; Sealed type: -15§ to 80§ C
- Humidity: General purpose type: 85% RH max.; Sealed type: 95% RH
- Service life: Mechanically: 20,000,000 operations min.; electrically: 500,000 operations min.
Product Specification of Micro Switches With Regular Or Sealed Operating Heads
- Ambient Temperature:General purpose type: -25 to +80
Sealed type: -15 to 80
- Dielectric Strength:1,000 VAC, 50/60 Hz for 1 minute between non-continuous terminals
2,000 VAC, 50/60 Hz for 1 minute between current-carry part and ground
- Initial Contact Resistance:15m Ω min. (at 500 VDC)
- Insulation Resistance:100M Ω min. (at 500 VDC)
- Operating Frequency:Mechanically: 240 operations/min.
Electrically: 20 operations/min.
- Operating Humidity:General purpose type: 85% RH max.
Sealed type: 95% RH
- Operating Speed:0.01mm to 1m/sec
- Rating:15A: 125 or 250V AC
1/8 HP: 125V AC
1/4 HP: 250V AC
1/2A: 125V DC
1/4A: 250V DC
- Service life:Mechanically: 20,000,000 operations min.
Electrically: 500,000 operations min.
- Shock:Mechanical durability: Approx 1,000m/sec (approx 100G`s)
Malfunction durability: Approx. 300m/sec (approx 30G`s)
- Vibration:Malfunction durability: 10 to 55Hz 1.5mm double amplitude