Product Profile of Limit Side Mount Switches
VG Electric offers Limit Side Mount Switches. VG Electric supplies micro switches; limit switches, Push Button switches, pilot /indicator lights, cam operated rotary switches, sensors, etc. Limit Side Mount Switches have momentary contacts and level or plunger operations.
Key Features of Limit Side Mount Switches
- Side mount switches
- Momentary contacts
- Level or plunger operation
- Regular or sealed operating heads
- Completely sealed construction.
- 1/2" conduit entry, captive cover screws
- Dustproof. Oil-Tight, Water-Resistant
- Temperature range +15§F to 175§F [-10§C to +80§C]
- Operating speed: 0.01mm to 1m/sec
- Operating frequency: Mechanically: 240 operations/min; Electrically: 20 operations/min.
- Contact resistance: 15m ? max. [initial]
- Insulation resistance: 100M ? min. [at 500 VDC]
- Dielectric strength: 1,000 VAC, 50/60 Hz for 1 minute between non-continuous terminals 2,000 VAC, 50/60 Hz for 1 minute between current-carrying part and ground
- Vibration: Malfunction durability: 10 to 55Hz 1.5mm double amplitude
- Shock: Mechanical durability: 1,000m/sec2 [approx. 100G`s]
- Malfunction durability: 300m/sec2 [approx. 30G`s]
- Ambient operating temperature: Operating: -10§ to +80§ C
- Humidity: General purpose type: 85% RH max; Sealed type: 95% RH
- Service life: Mechanically: 20,000,000 operations min.
- Electrically: 500,000 operations min.
- 15A 125, 250V
- 1/8HP 125V AC, 1/4HP 250V AC
- 1/2A 125V DC, 1/4A 250V DC
Product Specification of Limit Side Mount Switches
- Ambient Temperature:Operating: -10 to +80
- Dielectric Strength:1,000 VAC, 50/60 Hz for 1 minute between non-continuous terminals
2,000 VAC, 50/60 Hz for 1 minute between current-carrying part and ground
- Initial Contact Resistance:15m Ω max. (initial)
- Insulation Resistance:100M Ω min. (at 500 VDC)
- Operating Frequency:Mechanically: 240 operations/min.
Electrically: 20 operations/min.
- Operating Humidity:General purpose type: 85% RH max
Sealed type: 95% RH
- Operating Speed:0.01mm to 1m/sec
- Rating:15A 125, 250V
1/8HP 125V AC, 1/4HP 250V AC
1/2A 125V DC, 1/4A 250V DC
- Service life:Mechanically: 20,000,000 operations min.
Electrically: 500,000 operations min.
- Shock:Mechanical durability: 1,000m/sec2 (approx. 100G`s)
Mechanical durability: 1,000m/sec2 (approx. 100G`s)
Malfunction durability: 300m/sec2 (approx. 30G`s)
- Vibration:Malfunction durability: 10 to 55Hz 1.5mm double amplitude