Product Profile of Light Weight Switches With Plastic Enclosure
VG Electric supplies Light Weight Switches with Plastic Enclosure. VG Electric offers sensors, cam operated rotary switches, micro switches; limit switches, Push Button switches, pilot /indicator lights, etc. The Light Weight Switches with Plastic Enclosure are available with wide choice of head and actuators. These switches are widely used for electric and electronic purposes.
Key Features of Light Weight Switches With Plastic Enclosure
- Total plastic enclosure, light weight switches
- Wide choice of heads and actuators
- Captive cover screws
- Mode of operation is field adjustable
- Dustproof. Oil-Tight, Water-Resistant
- 2 circuits: 1 N.O., 1 N.C. contacts design
- Temperature range +5§F to +160§F [-15§C to +70§C]
- 6A: 125 or 250V AC
- 0.4A: 125V DC
- Operating speed: 0.5mm to 50m/sec
- Operating frequency: Mechanically: 120 operations/min.; Electrically: 30 operations/min.
- Contact resistance: 15m Ω max. [initial]
- Insulation resistance: 100M Ω min. [at 500 VDC]
- Dielectric strength: 1,000 VAC, 50/60 Hz for 1 minute between non-continuous terminals 1,500 VAC, 50/60 Hz for 1 minute between each terminal and non-current-carrying part and between each terminal and ground
- Vibration: Malfunction durability: 10 to 55Hz; 1.5mm double amplitude
- Shock: Mechanical durability: Approx. 1,000m/sec2 [approx. 100G`s]
- Malfunction durability: Approx. 300m/sec2 [approx. 30 G`s]
- Ambient operating temperature: Operating: -15§C to +70§C
- Humidity: 95% RH max
- Service life: Mechanically: 10,000,000 operations min.; Electrically: 500,000 operations min.
- Degree of protection: IEC 529 class IP65
Product Specification of Light Weight Switches With Plastic Enclosure
- Ambient Temperature:Operating: -15 to +70
- Dielectric Strength:1,000 VAC, 50/60 Hz for 1 minute between non-continuous terminals
1,500 VAC, 50/60 Hz for 1 minute between each treminal and non-current-carrying part and between each terminal and ground
- Initial Contact Resistance:15m Ω max. (initial)
- Insulation Resistance:100M Ω min. (at 500 VDC)
- Operating Frequency:Mechanically: 120 operations/min.
Electrically: 30 operations/min.
- Operating Humidity:95% RH max
- Operating Speed:0.5mm to 50m/sec
- Service life:Mechanically: 10,000,000 operations min.
Electrically: 500,000 operations min.
- Shock:Mechanical durability: Approx. 1,000m/sec2 (approx. 100G`s)
Malfunction durability: Approx. 300m/sec2 (approx. 30 G`s)
- Vibration:Malfunction durability: 10 to 55Hz; 1.5mm double amplitude