Product Profile of Over Load Safe Compression Load Cell
Over Load Safe Compression Load Cell is designed with rated load capacity of 1, 1.5, 2 and 2.5 Tons. The Compression Load Cell can operates in a temperature ranging between 0 degree C and 65 degree C. The Compression Load Cell of model LCS offers protection against 150% or 200% of over load rating. The Over Load Safe Compression Load Cell can be easily installed and offer good reliability.
Synapsis Techno Instruments manufactures Over Load Safe Compression Load Cell. Synapsis Techno Instruments offers a wide range of equipments in the field of industrial weighing and automation. The range of products include load cell, web tension controllers, load sensors, digital load indicators, weighing scale, over load protection system, bagging system, testing machine etc.
Key Features of Over Load Safe Compression Load Cell
- Easy to Install
- Good Reliability
- Good Repeatability
- Temperature Compensated
Product Specification of Over Load Safe Compression Load Cell
- Excitation Voltage:10 to 12 Volts DC/AC (RAAS)
- Hysteresis:+ - 0.25 % of Rated Output
- Input Resistance:350 + - 10 Ohms
- Load capacity:Rated Load Capacity : 1, 1.5, 2, 2.5 Tonne
- Model:LCS 13, 152, 23, 252
- Non Linearity:+ - 0.025 % of Rated Output
- Non-Repeatability:+ - 0.10 % of Rated Output
- Output Resistance:350 + - 3 Ohms
- Sensitivity:Rated Output Sensitivity : 2m V/V + - 0.25%
- Temperature Effect:Temperature Effect on Zero : 0.005 % of Rated Output /°C ; Temperature Effect on Output : 0.010 % of Rated Output /°C
- Temperature Range:Operatable Temperature Range : 0 °C to 65 °C ; Storage Temperature Range : -20 °C to 85 °C
- Zero Balance:2 % of Rated Output
- Load Rating:Over Load Rating, Safe : 150 % of Rated Capacity ; Over Load Rating (Ultimate) : 200 % of Rated Capacity