Product Profile of Tablet Disintegration Test Apparatus
Tablet Disintegration Test Apparatus has the feature of non volatile memory and on line/ off line print facility. The Apparatus has power failure indication program is incorporated and has password protection at different level. The Apparatus has the facility to print company’s name on test report and optically isolated electronic heater driver. The Tablet Disintegration Test Apparatus has facility to measure stroke length while test is on and the beaker temperature of both baskets is displayed individually.
Tablet Disintegration Test Apparatus is offered by Prolific Instrument. Prolific Instrument supplies analytical balance, counting scale, disintegration tester, gas chromatography, jewellery balance, lab water purification system, micro balance, bottle top dispenser, crane scale, friability test apparatus, hardness tester, titrator and melting point apparatus.
Key specifications of Tablet Disintegration Test Apparatus:
- Number of beakers: 2, 1000 ml glass beakers].
- Number of baskets: 2, each containing 6 glass tubes and 6 guided discs
- Number of cycles: 30 cycles/ minute
- Stroke length: 55 ± 2 mm.
- Power supply: 230 v, 50 hz, 1 kw maximum
- Timer maximum interval setting: 4 hours.
- Temperature range: room temperature to 45 ° c.
- Temperature resolution: ± 0.2 ° c.
- Dimensions: 390 X 360 X 570 mm
- Blue graphic LCD display.
- Input: tactile keypad + ps - 2/ pc keyboard.
- Memory to store 25 tests method parameters like disintegration time, temperature, alarm time and print interval.
- Compatible with dot matrix printer.
Key Features of Tablet Disintegration Test Apparatus
- Microcontroller based circuitry to precisely control, indicate and program temperature of water bath and beaker individually.
- Pause facility: this facility permits chemist to check disintegration state of the tablets intermittently and continue test without disturbing the test parameters.
- Equipped with maintenance free single stepper motor.
- All parameters like- set test time, actual test time, temperature, heaters on/ off state etc, are indicated on graphic LCD display screen.
- Protection for over temperature for heater through software and hardware.
- Software as well as hardware protection for over temperature of heater.
- Facility to measure stroke length while test is on.
- Beaker temperature of both baskets displayed individually.
- Test reports print all the detailed test parameters such as temperature, batch no, and product id etc with on-line or off-line printing facility.
- Facility to print companys name on test report.
- Optically isolated electronic heater driver.
- Password protection at different level.
- Non volatile memory.
- On line/ off line print facility.
- Date and item selection in off line printing.
- Power failure indication program is incorporated.
- IQ, OQ documents will be provided with the instrument.
- Validation of cycles/ minute with on/ off line printing facility.
- Facility to measure stroke length while test is on.