Product Profile of Continuous Rail Thermometer With Temperature Sensor Unit
Continuous Rail Thermometer with Temperature Sensor Unit provides for menu based user friendly man machine interface using keyboard and LCD display. The Continuous Rail Thermometer comes with two lines Alpha numeric LCD display of temperature in the range of 5 degree C to 85 degree C with accuracy of +/-1c and resolution of 0.1 c. The Continuous Rail Thermometer monitors the rail temperature continuously and stores the same in flash memory which has capacity to store temperature data on hourly basis for a long time. Continuous Rail Thermometer with Temperature Sensor Unit has the provision for printing logged data such as recorded maximum and minimum temperatures per day with time and date stamping for the stipulated period and maximum and minimum temperature attained in given period with time and date stamping.
Key Features of Continuous Rail Thermometer With Temperature Sensor Unit
- Provides for menu based user friendly man machine interface using keyboard and LCD display.
- Provides two lines Alpha numeric LCD display of temperature in the range of 5 degree C to 85 degree C with accuracy of +/-1c and resolution of 0.1c.
- Monitors the rail temperature continuously and stores the same in flash memory which has capacity to store temperature data on hourly basis for 18 months.
- Provision for printing logged data such as recorded maximum and minimum temperatures per day with time and date stamping for the stipulated period and maximum and minimum temperature attained in given period with time and date stamping.
- Scrolling provision for displaying logged data for suitable set period on the LCD display.
- RS232 port provided for connection of the CRT to PC.
- No interruption to temperature recordings while taking print outs.
- It shall support temperature sensor fitted on rail up to 100 meters through cable.
- Transfers the data recorded inside its data logger flash section to plug in type of data transfer Module [DTM] which can be connected to pc from where the same can be accessed in Excel files.
- The temperature sensing unit can be mounted on web of rail with out interrupting traffic.