Product Profile of Wind Alarm Control System With Alarm Muting Facility
Wind Alarm Control System with Alarm Muting Facility is ideal for surveillance of railway bridges, jetties, tall structures, off shore installations etc. The Wind Alarm Control System of model number WACS-100 uses a three cup magnetically coupled anemometer. The Wind Alarm Control System processes wind speed pulses through two independent paths; analog and digital, giving full redundancy. Wind Alarm Control System with Alarm Muting Facility is capable of retransmitting wind speed analog data over a secondary loop interfaced with yet another IB-2.
Core Technologies is the manufacturer of Wind Alarm Control System with Alarm Muting Facility. Core Technologies supplies various types of dynamic weighing machine controllers, tamper proof data loggers for pharmaceutical industry, high speed sequence of events recorders for power sector, weather monitoring stations, loop powered industrial transmitters, strain gauge instrumentation and automated test equipment for engineering test rigs.
Key Features of Wind Alarm Control System With Alarm Muting Facility
- Alarms can be interfaced with railway track signalling system to automatically prevent passage of trains over the bridge, whenever alarm conditions occur
- The system has facility to mute the alarm, at the discretion of supervisor or through automatic interlock with the track signalling system
- The system is capable of retransmitting wind speed analog data over a secondary loop interfaced with yet another IB-2
- Processes wind speed pulses through two independent paths; analog and digital, giving total redundancy
- Uses a three cup magnetically coupled anemometer.
- Immune to gust or lull from affecting the alarm annunciation.
- Simple and easy controls and an ergonomic design for a fool proof and dependable instrument system.
- Packaged in IP66 enclosure and uses components rated to work up to 65 ° C.
- It can withstand water submergence up to 3 m. and is resistant to corrosion.
- Processes wind speed pulses through two independent paths; analog and digital, giving 100% redundancy.
- In addition it has facility to check and cross refer sensor calibration built in the system.
- The main principle of the system, is based on the proven technology of data transmission over industrial 4-20mA current loop.
- Can be used for retransmission of data repeatedly for further distances in multiples of 5 Km, with no loss of accuracy.
- Loop powered operation isolates the system from dependence on mains
- Supply, usually the first casualty in a thunder storm.
- The instrument operates from a 24 volt battery and is isolated from the battery up to 500V AC.
- The 4-20 mA loop has inherent quality of detecting open or shorted loop conditions.
- In built protection and filters for lightening and lightning induced spikes as well as from accidental 230V AC line leakage.
- Sensor, Electronics hardware and the 24 Volt battery supply are totally isolated from each other.
- Simplicity of operation, provision of minimum important functions and ease of installation
- Provides potential free NC/NO contacts for interlocking with the external track signalling system.
- Provides for foolproof alarm acknowledge, both in normal to alarm and alarm to normal transitions.
- Caters to one sensor with one loop receiver alarm generator at up or down station.
- Can be further expanded by cascading any number of loops in a given direction, say "up".
- Railway Bridges
- Railway
- Tunnel entry and exits
- Tall buildings,
- Suspension bridge Towers
- Jetties
- projecting into sea
- Air Ports
- Dam sites
- Tall Chimneys
- Light Houses