Product Profile of Nucleonic Density Gauge In Stainless Steel Housing
Nucleonic Density Gauge in Stainless Steel Housing is equipped with Switch mode power supply of 88 to 264 Vac or 24VDC. The Nucleonic Density Gauge ensures that Data is transmitted by RS422 link. The Nucleonic Density Gauge has the control unit of IP 66 316 protection provided in stainless steel housing. The Nucleonic Density Gauge in Stainless Steel Housing is equipped with Radioisotope that is Double encapsulated in Cs 137 or Co 60.
NK Instruments Pvt. Ltd. Offers Nucleonic Density Gauge in Stainless Steel Housing. NK Instruments Pvt. Ltd. Supplies a wide range of process instruments for indication and control of process parameters like Pressure, Differential Pressure, Vacuum, Temperature, Level, Flow, Vibration, Moisture, Conductivity, TDS and Density. The range of products include pressure switches, differential pressure switches, vacuum switches, differential pressure gauge, flow meters, level switches, radar level transmitters, digital moisture meter, pressure transmitters, temperature switches, vibration switches etc.
Key Features of Nucleonic Density Gauge In Stainless Steel Housing
- Shielding meets or exceeds internationally accepted safety standards Rotary shutter with standardizing absorber incorporated
- Detector Housing: P67 Rugged steel enclosure or 316 Stainless Steel Connects to Control Unit with instrumentation cable
- Control Unit: IP 66 316 Stainless Steel housing
- Switch mode power supply: 88 to 264 Vac or 24Vdc
- Data transmitted: by RS422 link (Optional - Modbus RTU, Profibus DP Device Net, Hart Protocol, Foundation Fieldbus)
- No loss of data with power off
- Decay clock continues with power off
- May be up to 1000 meters from detector module
- Radioisotope: Double encapsulated Cs 137 or Co 60
Product Specification of Nucleonic Density Gauge In Stainless Steel Housing
- Detector:Scintillation Detector : Sodium Iodide with integral photo-multiplier
- Housings:Detector Housing : IP67 Rugged steel enclosure or 316 Stainless Steel Connects to Control Unit with instrumentation cable
- Humidity:5-95 % RH, non condensing
- Mass:Source Holder - 34 Kg, Detector Unit - 20 Kg, Control Unit - 6 Kg
- Operating Temperature:0 to 60 °C
- Outputs:Two 4-20ma current loops for SG, per cent solids, mass flow or temperature correct ed SG. Mass flow integrator with potential free make contacts one pulse per tonne
- Repeatability:0.0001 SG units typical, 0.0002 SG units maximum
- Temperature Drift:0.00003 SG units per degree Celsius
- Vibration:2g at 100 Hz