Proton Instruments Pvt. Ltd. Manufactures Triple-Axis Lump and Neck-down Detectors. Proton Instruments Pvt. Ltd. Is an ISO 9001 registered organization. Proton Instruments Pvt. Ltd. Offers instrumentation and control equipment for use in industrial production. The Triple-Axis Lump and Neck-down Detectors provides outstanding product quality supervision. The 3 LED Constant Light Sources cover the complete circumference of the product, and any immediate change in the surface pole is detected by the LED optical receiver, Alarming and Reporting the height, length and location of lumps and necks along and around the product. The Triple-Axis Lump and Neck-down Detectors are easy to install, integrate and use. This device can be used as a stand alone device or integrated to the machine PLC. Audio / Visual Alarm, Fault Printer and Datalogging PC Software are available to compliment the Lump and Neck Detector, closing the loop on Quality Control. The applications of Triple-Axis Lump and Neck-down Detectors include production processes such as Wire Drawing, Braiding, Cable Insulating and Jacketing, Rewinding and Coiling, Rubber and Plastic Extrusion Processes for Hose, Tube and Pipe production.
Product Specification of Triple-Axis Lump And Neck-Down Detectors
- Ambient Temperature:5°C ~ 45°C (41°C ~ 113°F)
- Analog Inputs:0 - 10 Vdc scalable input. For remote setting of flaw height
- Analog Outputs:3 x
(Option) ± 10 Vdc Scalable output. X, Y, Z
- Digital Inputs:2x
Max. input 24 Vdc. Length reset; End of reel / Print activation
- Fault Height:Min. 0.04 mm (0.0016 inch) + 1% of object diameter
Min. 0.5 mm (0.02 inch)
- Gate Size:30 mm (1.18 inch)
- Gauge Head Dimensions:50 x 320 x 292
- Gauge Weight:3 kg (6.6 lbs)
- Light Source:3 x LED
- Maximum Speed:2500 m/min (8200 ft/min) (dependent on fault length)
- Model:LN3030
- Number of Axes:3
- Object Size:Min. 0.4 mm (0.0018 inch)
Max. 25 mm (0.98 inch)
- Power Requirement:15 ~ 25 Vdc, 20 Watts max (with AiG2-LN display)
- Protection:IP67
- Relay Outputs:3 x
Volt-Free Contact; Max. Voltage 50 Vdc 0.5 A
Gauge OK, Lump, Neck
- Signal Processing Rate:200 kHz
- Speed Input:Analogue: 0 - 10 Vdc scalable.
Pulse: Max. frequency 250 kHz. Max pulse height 30 V. Scalable for exact speed.
- Time Between Faults:Min. User defined in the range 0.02 to 99 ms
- Tolerance Setting Range:0.04 to 10 mm (0.001 increments)
- Tolerance Setting Resolution:0.01