Product Profile of Frequency Converters For Defence And Aviation Industries
Total Power Conditioners Pvt. Ltd. Manufactures Frequency Converters for Defence and Aviation Industries. Total Power Conditioners Pvt. Ltd. Is an ISO 9001: 2000 certified company. The Frequency Converters for Defence and Aviation Industries are available for both single phase three phase input output with variable frequency from 60Hz to 400Hz. Frequency converter is designed for Defence establishments and aviation industries to give constant amplitude and frequency. These Frequency converters supply the required output as per the specification, and protect the equipment from the irregularities of the commercial mains supply. Frequency Converters for Defence and Aviation Industries are of superior design and quality. The Frequency converters are manufactured using the highest quality components, with precise assembly, subjected to high quality testing and inspection procedures.
Key Features of Frequency Converters For Defence And Aviation Industries
- AC Voltage : 230V/415VAC, -20% to +15%
- Phase : Single/Three
- Frequency : 50Hz +/-10%
- AC Voltage : 230V /415VAC +/-1%
- Phase : Single/Three
- Frequency : 60Hz to 400Hz +/-0.05%
- Power factor : 0.8 Lag
- Harmonic distortion : Up to 5%
- AC Voltage : 230V +/-1%
- Phase : Single
- Frequency : 60Hz to 400Hz +/-0.05%
- Power factor : 0.7lg to unity
- Waveform : Sinusoidal
- THD :
- Transient response : +/-5% for a step load of 100%
- Recovery :
- Load crest factor : 3:1
- Full protection : Under/Over voltage, Overload, Short circuit, AC/DC fuse
- Indications
- LED : Mains ON, Mains fail, Charger ON, Inverter ON, Battery LOW
- Audio Alarm : Battery LOW, Mains fail, Inverter OVERLOAD
- Performance features
- Isolation : Output is completely isolated from Input
- Overload capacity : 120% for 10min, 150% for 5sec
- Cooling system : Forced Air
- Temperature : 0 to 50 deg C
- Humidity : 20 to 90% non condensing
- Noise level :
Product Specification of Frequency Converters For Defence And Aviation Industries
- Cooling System:ForcedAir
- Distortion:Up to 5%
- Indications:MainsON,Mainsfail,ChargerON,InverterON,Battery LOW
- Input Frequency Range:50Hz±10%
- Input Voltage:230V/415VAC,-20%to +15%
- Isolation:Output is completely isolated from Input
- Load Crest Factor:3:1
- Noise Level:<50
- Operating Humidity:20 to 90%non condensing
- Operating Temperature:0 to 50
- Output Frequency:60Hzto 400Hz±0.05%
- Output Voltage:230V/415VAC±1%
- Overload Capacity:120%for 10min, 150%for 5sec
- Phase:Input: Single/Three
Output: Single/Three
- Power Factor:0.8Lag
- Transient Response:±5%for astep load of 100%
- Waveform:Sinusoidal
- Transient Recovery:<10msec
- Protection:Under/Over voltage,Overload,Short circuit, AC/DCfuse
- Alarm:Battery LOW,Mainsfail, InverterOVERLOAD