Product Profile of Radioassay Counter for Radiation Measurement
Vel Electronics offers Radioassay Counter for Radiation Measurement. Vel Electronics supplies induction heating equipments of varying power capacities & frequencies. Radioassay Counter for Radiation Measurement has been widely used in the medical files. Radioassay Counter for Radiation Measurement plays an important role in pathological tests for estimation of a number of important biological ingredients. Radioassay Counter for Radiation Measurement containing all essential reagent and biological ingredient are locally available, or can be easily imported. Radioimmunoassay of insulin, T-3, T-4, HGH, HPL, Vitamin B-121 and many others are routinely carried out by a large number of pathological labs, hospitals and medical research institutions throughout India.
The technical specifications of Radioassay Counter for Radiation Measurement are as follows:
- Detector shield: 3 mm Powder coated M.S + 5 mm lead + 3mm stainless steel. Provision to remove shield during
Transportation.
- High Voltage: 500 - 1000Volts D.C.[ Factory adjusted]; electronically regulated and stabilised.
- Amplifier: Pulse amplifier with cr-rc pulse shaping: Gain 100
- Analyzer: Single channel analyzer with base line and window adjustment from 10 keV to 1010 KeV by 10 turn heliports and direct reading duo dials on front panel.
Product Specification of Radioassay Counter for Radiation Measurement
- Control:Mains ON-OFF, and fuse on near panel preset time selector, start, stop, and reset- front panel switches.
- Stability:Better than 0.5% for 5 minutes counting time.
- Detector:Integral Line assembly consisting of a 35 mm diax35mm height, Sodium iodide Thallium activated crystal [NaI(TI)], Optically couples to a 32 mm dia high gain photomultiplier. Central well 19 mm diax25mm deep for high efficiency counting of samples in PVC tubes. Effficiency for 1-125 at well bottom better than 65%
- Detector shield:3 mm Powder coated M.S + 5 mm lead + 3mm stainless steel. Provision to remove shield during transportation.
- High Voltage:500 - 1000Volts D.C.( Factory adjusted); electronically regulated and stabilised.
- Amplifier:Pulse amplifier with cr-rc pulse shaping: Gain 100
- Analyzer:Single channel analyzer with base line and window adjustment from 10 keV to 1010 KeV by 10 turn helipots and direct reading duodials on front panel.
- Timer:Preset counting times of 30 seconds 1 minute and 5 minutes; Stability and accuracy better than 0.1 percent.
- Scaler:Large 1 inch height six digit liquid crystal display of accumulated counts with 10:1 contrast ratio
- R.F.Filter:In A.C. Mains Circuit for suppression of R.f noise and interference
- Power:230 VoltsĀ±10% 50 Hz A.C. Mains. Power consumption less than 5 Watts.
- Housings:Powder coated aluminum cabinet of attractive sober color and anodized front panel in two color.