Prism Gas Detection Pvt. Ltd. Supplies HCFC/HFC Detector. Prism Gas Detection Pvt. Ltd. Is an ISO 9000 certified company. HCFC/HFC Detector or XP 704 works on the detection principle of hot wire semi-conductor. Compact in design and structure, this equipment is light weight and offers superior performance with utmost reliability.
Features of HCFC/HFC Detector:
Newly developed low-power hot wire semi-conductor sensor for HCFCs and HFCs realized super-sensitive detection
Compact, lightweight, and easy to use
Extractive type
Detection indicated in two ways: lamp and buzzer
Sensitive than leak detection liquid like soapy water, etc
Easier to use
Specifications:
Gas Detected: R-22, R-123, R-23, R-32, R-134a, R-142b, R-404A, R-407A, R-407C, R-407E, R-410A, R-507A, R-290, R-600a, R-707
Minimum Detectable Concentration: 5ppm
Minimum Detectable Leak Rate: 2.1 x 10-6 Pa m/s 2.8g/year leak
Response Time: 10s or less
Detection Indication: Intermittent buzzer and flashing lamp
Power source: 4 x AA [R6] dry cells
Battery life: *1 Approx. 3 continuous hours [by manganese dry cells]; Approx. 9 continuous hours [by alkaline dry cells]
Operating Temperature: 0 to 400 degree C
|